Evaluación del aislamiento térmico en la red de vapor y la eficiencia del caldero pirotubular de 30 BHP del Hospital la Caleta
DOI:
https://doi.org/10.18050/ingnosis.v7i2.2180Keywords:
Thermal insulation, boiler efficiency, steam network, combustion gases, paybackAbstract
The general objective of the research work was to evaluate the thermal insulation applied in the steam network and as a consequence evaluate the efficiency before the application of said insulation and see the impact that it generates after its application in the 30 BHP firetube boiler. from hospital la Caleta, 2021. Likewise, for its development, measurements were taken of said steam network which feeds the kitchen, laundry and autoclaves area, as well as a sampling of the gases produced by combustion was carried out, for this an instrument was used. such as; gas analyzer and tape measure for steam network dimensions; Likewise, after being able to quantify the heat losses to determine the efficiency of the 30 BHP fire tube boiler by indirect method according to the Peruvian Technical Standard, determining the production, production indicators and steam cost, the optimal thickness of thermal insulation was calculated by apply to the steam network and finally to carry out the same calculation procedure for the boiler after the application of said insulation. On the other hand, the annual money savings and payback for the application of thermal insulation were calculated.
References
Guevara, R. (2013). Manual de uso interno de Plantas Consumidoras de Energía. E.A.P. Ing. En Energía, Universidad Nacional del Santa. Ancash, Perú.
Limone, C. (2012). Diseño e Instalación de Aislante Térmico en Tuberías y Equipos. Universidad Simón Bolívar. Caracas, Venezuela.
Shapiro, H. (2004). Fundamentos de Termodinámica Técnica. Segunda edición. Editorial Reverté, S.A. Disponible en: https://www.academia.edu/28426234/Fundamentos_de_Termodinamica_Tecnica_Shapiro_Moran_2_Edici%C3%B3n_2_
Aristizabal, C; Schafer, G; Barrera, R. (2014). Analyses of energetic and economic losses for the steam transport by pipes without and adequate thermal insulation. Análisis de pérdidas energéticas y económicas por transporte de vapor en tuberías sin un adecuado aislamiento térmico. Disponible en: https://revistas.udistrital.edu.co/index.php/REDES/article/view/6358
Chepe, C; Nuñez, S. (2018). Diseño de un sistema de aislamiento térmico para la red de tuberías de vapor en la empresa agroindustrial Pucalá S.A.C. Disponible en: https://repositorio.uss.edu.pe/handle/20.500.12802/4872
Ruiz, E. (2016). Determinación de la Eficiencia del Caldero de 30 BHP del Hospital la Caleta”. Universidad del Nacional del Santa. Ancash, Perú.
Rodríguez, O. (2014). Diseño del sistema de distribución de vapor y selección del caldero para el hospital San Juan de Dios. Universidad Politécnica Salesiana. Cuenca, España. Disponible en: https://dspace.ups.edu.ec/handle/123456789/7026
Catálogo de Aislamiento Térmico FiberGlass Isover Colombia. (2018). Disponible en: https://www.isover.com.co/
Guía para la calificación de consultores en eficiencia energética – Agencia Chilena de Eficiencia Energética. Disponible en: old.acee.cl/577/articles-62222_recurso_3.pdf
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 INGnosis
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.